BLOOD
GROUPING & CROSS MATCHING TECHNIQUE
|
|
![]() |
|
Specimens
Required
|
|
|
|
A specimen
of the Recipient's blood (patient's blood ) or the Donor's blood sample
sent by the doctor/hospital is required in two containers :
|
|
|
The quantities mentioned above need not be strictly adhered to.
|
|
|
Check the labels before accepting the samples.
|
|
|
Beware of common names like "Usha Shah" and "Paresh Mehta".
|
|
|
In case two specimens bearing similar names are received mark them with some identifying mark or adding the referring doctor's name to the label (make similar additions in our records also). We are expected to keep all blood samples at least for one week. Similar names may cause confusion there. |
|
Equipment
& Reagents
|
||
|
|
Large & small glass tubes in appropriate racks
|
|
|
|
Glass markers or self-sticking labels for tubes
|
|
|
|
Microscope slides
|
|
|
|
Pasteur pipettes
with rubber teats |
|
|
|
Normal saline and
distilled water in appropriate containers |
|
|
|
Blood Grouping Sera
(anti-A, Anti - B and Anti - D), Bovine Albumin, Coombs' Serum |
|
|
|
Three panels of
pooled cells of Blood Group A, B and O |
|
|
|
Centrifuge machine
with accessories |
|
|
|
Microscope |
|
|
|
Record
books and registers and writing implements |
|